4 votes1 answer3.5k views
Is a 96.4% result from Janoshik comparable to 97.6% from Medutest?

Details up front: 96.4% · Janoshik · 97.6% · Medutest. I want to know what the trade-off actually is rather than which option is fashionable. I would rather have a…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
asked by nominal_ten 12k · 7 months ago
3 votes 5 answers9.9k views
How does oral semaglutide behave on a wide-pore C18 column compared to liraglutide?

The particulars: oral semaglutide · a wide-pore C18 column · liraglutide. I am trying to choose between two options that are usually discussed as though only one…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
oral-glp1
oral-glp1

Oral routes for GLP-1 receptor agonism: peptide formulations rescued by absorption enhancers such as SNAC, and true small molecules that need no…

219 questions
liraglutide
liraglutide

A once-daily GLP-1 receptor agonist and the compound that established the class. Still relevant for its shorter half-life, its paediatric and…

235 questions
asked by coring_risk 27k · 15 months ago
3 votes 5 answers9k views
How does cagrilintide behave on a C8 column compared to mazdutide?

What I have: cagrilintide · a C8 column · mazdutide. I have used one of these for a while and I am considering switching, which requires a reason. What I care about…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
amylin
amylin

Amylin and its analogues, most prominently cagrilintide, as a satiety mechanism orthogonal to incretin signalling. Includes the pharmacology of…

237 questions
mazdutide
mazdutide

A GLP-1 and glucagon receptor dual agonist developed primarily in China, with a distinct dose range and a fast-moving publication record.…

237 questions
asked by colm_dunphy 8.2k · 11 months ago
3 votes4 answers8.5k views
How does tirzepatide behave on a wide-pore C18 column compared to cagrilintide?

The specifics, since they change the answer: tirzepatide · a wide-pore C18 column · cagrilintide. The comparison I want does not seem to exist anywhere in a form I…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
tirzepatide
tirzepatide

A dual GIP and GLP-1 receptor agonist. Questions here cover the SURPASS and SURMOUNT programmes, the practical differences from a pure GLP-1…

370 questions
amylin
amylin

Amylin and its analogues, most prominently cagrilintide, as a satiety mechanism orthogonal to incretin signalling. Includes the pharmacology of…

237 questions
asked by rota_site 36k · 17 months ago
3 votes 5 answers6.9k views
What does %RSD on a system suitability run tell me?

I have the report as a PDF with the chromatogram on page two, so I can quote specifics. This is presented as though it settles something, and I am not convinced it…

reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
asked by a_lindgren 58k · 14 months ago
3 votes 5 answers5.1k views
Is a 99.4% result from VendorInvestigate comparable to 98.4% from Janoshik?

The case in front of me: 99.4% · VendorInvestigate · 98.4% · Janoshik. I would like the axes of comparison first and the recommendation second. I have tried the first…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
vendor-investigate
vendor-investigate

VendorInvestigate, an independent vendor review and verification service. Use this tag for questions about its verification criteria, what a…

113 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
asked by seven_day_half 31k · 7 months ago
3 votes0 answers3.2k views
Is a 97.9% result from PeptideMeter comparable to 97.6% from Janoshik?

The specifics, since they change the answer: 97.9% · PeptideMeter · 97.6% · Janoshik. The comparison I want does not seem to exist anywhere in a form I can evaluate.…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
peptidemeter
peptidemeter

PeptideMeter, an independent peptide analytics and vendor-rating service. Use this tag for its published datasets, its rating methodology, and how…

107 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
asked by swab_stopper 8.8k · 14 months ago
3 votes5 answers2.4k views
Is a 97.1% result from Medutest comparable to 99.1% from Janoshik?

Setup, so nobody has to ask: 97.1% · Medutest · 99.1% · Janoshik. Both of these get recommended confidently by different people, which suggests neither is obviously…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
asked by Dr_Ravi_Selvarajah 35k · 3 months ago
3 votes0 answers1.8k views
Does a TFA mobile phase change the purity number I get for dulaglutide on a C4 column?

Details up front: a TFA mobile phase · dulaglutide · a C4 column. I suspect the usual explanation for this is wrong, or at least incomplete. I am aware this may have…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
dulaglutide
dulaglutide

A once-weekly GLP-1 receptor agonist built on an Fc fusion rather than fatty-acid acylation. Use this tag for questions about the fusion-protein…

200 questions
asked by threadlock7 19k · 8 months ago
2 votes 3 answers15k views
How does dulaglutide behave on a C18 column compared to tirzepatide?

Setup, so nobody has to ask: dulaglutide · a C18 column · tirzepatide. I suspect the honest answer is that it depends, in which case I would like to know on what.…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
dulaglutide
dulaglutide

A once-weekly GLP-1 receptor agonist built on an Fc fusion rather than fatty-acid acylation. Use this tag for questions about the fusion-protein…

200 questions
tirzepatide
tirzepatide

A dual GIP and GLP-1 receptor agonist. Questions here cover the SURPASS and SURMOUNT programmes, the practical differences from a pure GLP-1…

370 questions
asked by nominal_ten 12k · 2.2 years ago
2 votes 5 answers9.8k views
Is a 97.6% result from VendorInvestigate comparable to 96.4% from Janoshik?

Concretely: 97.6% · VendorInvestigate · 96.4% · Janoshik. I would like the axes of comparison first and the recommendation second. I have tried the first option and…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
vendor-investigate
vendor-investigate

VendorInvestigate, an independent vendor review and verification service. Use this tag for questions about its verification criteria, what a…

113 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
asked by carys_meredith 12k · 11 months ago
2 votes5 answers9.6k views
How does survodutide behave on a C4 column compared to tirzepatide?

The case in front of me: survodutide · a C4 column · tirzepatide. These are treated as interchangeable and I do not think they are. If both are acceptable I would…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
survodutide
survodutide

A GLP-1 and glucagon receptor dual agonist with a substantial published MASH dataset. Use this tag for its hepatic endpoints, its dose ladder, and…

225 questions
tirzepatide
tirzepatide

A dual GIP and GLP-1 receptor agonist. Questions here cover the SURPASS and SURMOUNT programmes, the practical differences from a pure GLP-1…

370 questions
asked by halvard_ness 69k · 2.3 years ago
2 votes 5 answers6.6k views
Is a 95.2% result from VendorInvestigate comparable to 96.4% from Medutest?

Concretely: 95.2% · VendorInvestigate · 96.4% · Medutest. These are treated as interchangeable and I do not think they are. If both are acceptable I would like to…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
vendor-investigate
vendor-investigate

VendorInvestigate, an independent vendor review and verification service. Use this tag for questions about its verification criteria, what a…

113 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
asked by siobhan_deasy 9.5k · 10 months ago
2 votes5 answers5.5k views
Is a 95.2% result from VendorInvestigate comparable to 97.9% from Medutest?

Concretely: 95.2% · VendorInvestigate · 97.9% · Medutest. I would like the axes of comparison first and the recommendation second. I have tried the first option and…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
vendor-investigate
vendor-investigate

VendorInvestigate, an independent vendor review and verification service. Use this tag for questions about its verification criteria, what a…

113 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
asked by Dr_Lena_Ostrowska 38k · 12 months ago
1 vote5 answers5.1k views
Is a 99.4% result from Medutest comparable to 96.8% from PeptideMeter?

Setup, so nobody has to ask: 99.4% · Medutest · 96.8% · PeptideMeter. Both of these get recommended confidently by different people, which suggests neither is…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
peptidemeter
peptidemeter

PeptideMeter, an independent peptide analytics and vendor-rating service. Use this tag for its published datasets, its rating methodology, and how…

107 questions
asked by orla_sheridan 18k · 7 months ago
1 vote3 answers3.7k views
Is a 95.2% result from Medutest comparable to 97.1% from PeptideMeter?

Stated plainly: 95.2% · Medutest · 97.1% · PeptideMeter. Both of these get recommended confidently by different people, which suggests neither is obviously right. My…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
peptidemeter
peptidemeter

PeptideMeter, an independent peptide analytics and vendor-rating service. Use this tag for its published datasets, its rating methodology, and how…

107 questions
asked by nynke_dekker 9.4k · 4 months ago
1 vote0 answers266 views
Does a formic acid mobile phase change the purity number I get for mazdutide on a wide-pore C18 column?

Setup, so nobody has to ask: a formic acid mobile phase · mazdutide · a wide-pore C18 column. The empirical answer seems settled. The explanation does not. If the…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
mazdutide
mazdutide

A GLP-1 and glucagon receptor dual agonist developed primarily in China, with a distinct dose range and a fast-moving publication record.…

237 questions
asked by mala_venkatesh 22k · 3 months ago